PRAXAIR INC -- NITROGEN COMPRESSED -- 4210-01-443-6728
===================== Product Identification =====================
Product ID:NITROGEN COMPRESSED
MSDS Date:10/01/1997
FSC:4210
NIIN:01-443-6728
Status Code:A
=== Responsible Party ===
Company Name:PRAXAIR INC
Address:39 OLD RIDGEBURY RD
City:DANBURY
State:CT
ZIP:06817-0001
Country:US
Info Phone Num:800-772-9247
Emergency Phone Num:800-645-4633/800-424-9300(CHEMTREC)
Chemtrec Ind/Phone:(800)424-9300
CAGE:0LV01
=== Contractor Identification ===
Company Name:FIRE COMBAT INC
Address:2650 INDUSTRIAL PKY
Box:407
City:MARINETTE
State:WI
ZIP:54143-3821
Country:US
Phone:715-735-9058
Contract Num:SP0560-99-M-H063
CAGE:64903
Company Name:PRAXAIR, INC.
Address:39 OLD RIDGEBURY RD
Box:City:DANBURY
State:CT
ZIP:06810-5113
Country:US
Phone:800-772-9247; 800-PRAXAIR
CAGE:0LV01
Company Name:SAFETY EQUIPMENT CO
Address:6507 N HARNEY RD
Box:City:TAMPA
State:FL
ZIP:33610
Country:US
Phone:800-226-4732
CAGE:7T042
============= Composition/Information on Ingredients =============
Ingred Name:NITROGEN
CAS:7727-37-9
RTECS #:QW9700000
> Wt:99.
Other REC Limits:NONE RECOMMENDED
ACGIH TLV:ASPHYXIANT; 9596
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: ASPHYXIANT. EFFECTS
DUE TO LACK OF OXYGEN. MODERATE CONCENTRATIONS MAY CAUSE HEADACHE,
DROWSINESS, DIZZINESS, EXCITATION, EXCESS SALIVATION, VOMITING AND
UNCONSIOUSNESS. LACK OF OX YGEN CAN KILL. SKIN: NO HARM EXPECTED.
INGESTION: PRODUCT IS A GAS AT NORMAL TEMPERATURE AND PRESSURE.
EYE: NO HARM EXPECTED. CHRONIC: NO HARM EXPECTED.
Explanation of Carcinogenicity:PER MSDS:NITROGEN NOT LISTED BY NTP,
OSHA, OR IARC.
Effects of Overexposure:NITROGEN IS AN ASPHYXIANT. HEADACHE,
DROWSINESS, DIZZINESS, EXCITATION, EXCESS SALIVATION, VOMITING AND
UNCONSIOUSNESS. LACK OF OXYGEN CAN KILL.
Medical Cond Aggravated by Exposure:TOXICOLOGY & PHYS/CHEM PROPERTIES
OF NITROGEN SUGGEST THAT OVEREXPOSURE IS UNLIKELY TO AGGRAVATE
EXISTING MEDICAL CONDITIONS.
======================= First Aid Measures =======================
First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING GIVE
ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, QUALIFIED
PERSONNEL MAY GIVE OXYGEN. CALL A PHYSICIAN. SKIN: FLUSH WITH
WATER. INGESTION: PRO DUCT IS A GAS @ NORMAL TEMPERATURE &
PRESSURE. EYE: FLUSH WITH WARM WATER.HOLD EYELIDS OPEN,AWAY FRM
EYEBALLS TO ENSURE THAT ALL SURFACES ARE FLUSHED THOROUGHLY. NOTES
TO DR: NO SPECIFIC ANTIDOTE. PR ODUCT IS NEARLY INERT. TREATMENT
OF OVEREXPOSURE SHOULD BE DIRECTED AT CONTROL OF SYMPTIONS AND
THE CLINICAL CONDITION
===================== Fire Fighting Measures =====================
Lower Limits:N/APPLICABLE
Upper Limits:N/APPLICABLE
Extinguishing Media:NITROGEN CANNOT CATCH FIRE. USE MEDIA APPROPRIATE
FOR SURROUNDING FIRE.
Fire Fighting Procedures:CAUTION! HIGH PRESSURE GAS. EVACUATE ALL
PERSONNEL FRM DANGER AREA. IMMEDIATELY DELUGE CYLINDERS WITH WATER
FROM MAXIMUM DISTANCE UNTIL COOL, THEN MOVE AWAY FROM AREA IF WITH
OUT RISK. SELF CONTAINED BREATHING APPRATTUS MAY BE REQUIRED
BYRESCUE WORKERS. ON-SITE FIRE BRIGADES MUST COMPLY WITH OSHA 29
CFR 1910.156.
Unusual Fire/Explosion Hazard:NITROGEN CANNOT CATCH FIRE.HEAT OF FIRE
CAN BUILD PRESSURE IN CYLINDER AND CAUSE IT TO RUPTURE. NO PART OF
CYLINDER SHOULD BE SUBJECT TO A TEMPERATURE HIGHER THAN 125 DEG F
(52 DEG C). NITROGEN CYLIND ERS ARE EQUIPPED WITH A PRESSURE
RELIEFDEVICE (EXCEPTIONS MAY EXIST WHERE AUTHORIZED BY DOT).
================== Accidental Release Measures ==================
Spill Release Procedures:CAUTION! HIGH PRESSURE GAS. IMMEDIATELY
EVACUATE ALL PERSONNEL FROM DANGER AREA. NITROGEN IS ASPHYXIANT.
LACK OF OXYGEN CAN KILL. USE SELF CONTAINED BREATHING APPRATTUS
WHERE NEEDED. SHUT OFF FLOW I F YOU CAN DO SO WITH OUT RISK.
VENTILATE AREA OR MOVE CYLINDER TO WELL VENTILATED AREA. TEST FOR
SUFFICIENT OXYGEN EXPECIALLY IN CONFINED SPACES BEFORE ALLOW ING
REENTRY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE/ USE WITH ADEQUATE VENTILATION.
FIRMLY SECURE CYLINDERS UPRIGHT TO KEEP FROM FALLING OR BEING
KNOCKED OVER. SCREW VALVE PROTECTION CAP FIRMLY IN PLACE BY HAND.
STORE FULL & EMPTY CYLINDERS SEPAR ATELY. USE FIRST-IN, FIRST-OUT
INVENTORYSYSTEM TO PREVENT STORING FULL CYLINDERS FOR LONG PERIODS.
Other Precautions:PROTECT CYLINDERS FROM DAMAGE. USE SUITABLE HAND
TRUCK TO MOVE CYLINDERS; DO NOT DRAG, ROLL, SLIDE, OR DROP. NEVER
ATTEMPT TO LIFT CYLINDER BY ITS CAP; THE CAP IS INTENDED SOLELY TO
PROTECT THE VALVE. NEVER INSERT AN OBJECT (E.G. WRENCH,
SCREWDRIVER, PRY BAR) INTO CAP OPENING; DOING SO MAY DAMAGE (
SUPPLEMENT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED UNDER NORMAL USE. HOWEVER, AIR
SUPPLIED RESPIRATORS ARE REQUIRED WHILE WORKING IN CONFINED SPACES
WITH THIS PRODUCT. RESPIRATORY PROTECTION MUST CONFORM TO OSHA
RULES SPECIFIED IN 29 CFR 1910.134.
Ventilation:LOCAL EXHAUST IF NECESSARY, TO PREVENT OXYGEN DEFICIENCY.
MECHANICAL(GEN)-MAY BE ACCEPTABLE IF IT CAN MAINTAIN ADEQUATE
SUPPLY OF AIR.
Protective Gloves:WORK GLOVES WHEN HANDLING CYLINDERS.
Eye Protection:SAFETY GLASSES WHEN HANDLING CYLINDERS.
Other Protective Equipment:METATARSAL SHOES FOR CYLINDER HANDLING.
SELECT IAW OSHA 29CFR1910.132 AND 1910.133. REGARDLESS OF
PROTECTIVE EQUIPMENT, NEVER TOUCH LIVE ELECTRICAL PARTS.
Work Hygienic Practices:NONE PROVIDED BY MFR.
Supplemental Safety and Health
THE VALVE AND CAUSE A LEAK. USE AN ADJUSTABLE STRAP WRENCH TO REMOVE
OVER-TIGHT OR RUSTED CAPS. OPEN VALVE SLOWLY. IF VALVE IS HARD TO
OPEN, DISCONTINUE USE AND CONTACT YOUR SUPPLIER.
================== Physical/Chemical Properties ==================
HCC:G3
Boiling Pt:=-195.6C, -320.4F
B.P. Text:(1 ATM)
Melt/Freeze Pt:=-209.7C, -345.8F
M.P/F.P Text:(1 ATM)
Decomp Temp:Decomp Text:NP
Vapor Density:.072LB/FT3
Spec Gravity:0.967
Solubility in Water:0.023% @ 32 DEG F
Appearance and Odor:COLORLESS, ODORLESS, TASTELESS GAS AT NORMAL
TEMPERATURE & PRESSURE.
Percent Volatiles by Volume:100
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE CURRENTLY KNOWN. NITROGEN IS CHEMICALLY INERT.
Stability Condition to Avoid:UNDER CERTAIN CONDITIONS, NITROGEN CAN
REACT VIOLENTLY WITH LITHIUM, NEODYMIUM, TITANIUM, & MAGNESIUM TO
FORM NITRIDES. AT HIGH TEMP CAN ALSO COMBINE WITH OXYGEN AND
HYDROGEN.
Hazardous Decomposition Products:NONE
Conditions to Avoid Polymerization:WILL NOT OCCUR
=================== Toxicological Information ===================
Toxicological Information:NITROGEN IS A SIMPLE ASPHYXANT.
===================== Ecological Information =====================
Ecological:NO ADVERSE ECOLOGICAL EFFECT EXPECTED. NITROGEN DOES NOT
CONTAIN ANY CLASS I OR CLASS II OZONE-DEPLETING CHEMICALS. NITROGEN
IS NOT LISTED AS A MARINE POLLUTANT BY DOT.
==================== Disposal Considerations ====================
Waste Disposal Methods:PREVENT WASTE FROM CONTAM SURROUNDING
ENVIROMENT. KEEP PEOPLE AWAY. DISCARD ANY PROD,RESIDUE,DISPOSABLE
CNTNR/LINER IN ENVIROMENTALY ACCEPTABLE MANNER IN FULL COMPLIANCE
W/FED/STATE/LOCAL REGS. IF NEC ESSARY CALL YOUR LOCAL SUPPLIER FOR
ASSISTANCE.
=================== MSDS Transport Information ===================
Transport Information:NITROGEN, CMPRESSED,2.2,UN1066. LABEL=
NON-FLAMMABLE GAS.
===================== Regulatory Information =====================
SARA Title III Information:UNDER CERCLA RQ= NONE. SEC 302/304: TPQ=
NONE, EXTREMELY HAZ SUBSTANCE= NONE. SEC 311/312: HAZ CATEGORIES;
PRESSURE = YES, IMMEDIATE, DELAYED, FIRE, REACTIVITY = NONE. SEC
313 REPORTING OF RELEASE OF TOXIC CHEM THAT APPEAR ON 40 CFR 372 =
NOT REQUIRED. 40 CFR 68: NOT LISTED AS A REGULATED SUBSTANCE.
Federal Regulatory Information:NITROGEN IS LISTED ON THE TSCA
INVENTORY. 29 CFR 1910.119 : NITROGEN IS NOT LISTED IN APPENDIX A
AS A HIGHLY HAZARDOUS CHEMICAL.
State Regulatory Information:CA PROP 65: NOT LISTED. PENNSYLVANIA: THIS
PRODUCT IS SUBJECT TO THE WORKER AND COMMUNITY RIGHT TO KNOW ACT
(35 P.S. SEC 7301-7320).
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.