WHITTAKER CLARK & DANIELS INC -- MICA -- 6850-00N036283
===================== Product Identification ===================== Product ID:MICA MSDS Date:05/01/1992 FSC:6850 NIIN:00N036283 === Responsible Party === Company Name:WHITTAKER CLARK & DANIELS INC Address:1000 COOLIDGE ST City:SOUTH PLAINFIELD State:NJ ZIP:07080 Country:US Info Phone Num:908-561-6100;800-732-0562 Emergency Phone Num:908-561-6100;800-732-0562 CAGE:87775 === Contractor Identification === Company Name:WHITTAKER CLARK AND DANIELS INC Address:1000 COOLIDGE ST Box:City:SOUTH PLAINFIELD State:NJ ZIP:07080 Country:US Phone:908-561-6100/8007320562 CAGE:87775 ============= Composition/Information on Ingredients ============= Ingred Name:MICA - SILICATES (< 1% CRYSTALLINE SILICA) CAS:12001-26-2 RTECS #:VV8760000 OSHA PEL:20 MPPCF ACGIH TLV:3 MG/M3 RDUST; 9293 Ingred Name:CRYSTALLINE SILICA-QUARTZ CAS:14808-60-7 RTECS #:VV7330000 OSHA PEL:SEE TABLE Z3 ACGIH TLV:0.1 MG/M3 RDUST;9293 ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO Health Hazards Acute and Chronic:MAY CAUSE DELAYED RESPIRATORY DISEASE IF DUST IS INHALED OVER A PROLONGED PERIOD. Explanation of Carcinogenicity:CRYSTALLINE SILICA-QUARTZ:GROUP 2A,IARC,VOL 7,P.341,1987; ANTICIPATED TO BE CARC, NTP 6TH ANNUAL RPT ON CARC,1991. Effects of Overexposure:SEE HEALTH HAZARDS. Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER. ======================= First Aid Measures ======================= First Aid:INHALATION: REMOVE FROM EXPOSURE. SUPPORT BREATHING (GIVE ARTIFICIAL RESPIRATION/OXYGEN) . INGESTION: CALL MD IMMEDIATELY . SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER . EYE: FLUSH WIT H WATER FOR AT LEAST 15 MINUTES . ===================== Fire Fighting Measures ===================== Flash Point:NON-FLAMMABLE Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS . Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT . Unusual Fire/Explosion Hazard:NONE. ================== Accidental Release Measures ================== Spill Release Procedures:SWEEP UP OR VACUUM SPILLED MATERIAL. Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:NONE. Other Precautions:NONE. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:USE A NIOSH/MSHA APPROVED RESPIRATOR WHILE DUST CONCENTRATIONS ARE ABOVE TLV. Ventilation:GENERAL VENTILATION SUFFICIENT TO KEEP AIRBORNE CONCENTRATION BELOW CURRENT EXPOSE LIMITS . Protective Gloves:IMPERVIOUS GLOVES . Eye Protection:CHEMICAL WORKERS GOGGLES . Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER. Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER. Supplemental Safety and Health ================== Physical/Chemical Properties ================== HCC:N1 Spec Gravity:2.6-3.2 Evaporation Rate & Reference:0 Solubility in Water:NEGLIGIBLE Appearance and Odor:WHITE TO BUFF ODORLESS POWDER. Percent Volatiles by Volume:0(WT) ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES NONE. Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. Hazardous Decomposition Products:NONE. ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.